DirectNET

Data Center Management Solutions including UPS Systems, Data Center Cooling, KVM over IP & IP Power Strips, Server Racks and Server Rack accessories; KVM Switches and KVM Extenders; Rackmount Monitors and Rackmount Keyboards.


NAVIGATION
Home
Store
INSIDE MAC
Television Shows
Broadcast Shows
Daily News Shows
Special Shows
EVENTS
DAILY TIPS
Design
Mac OS X
Mac OS X UNIX
COMMUNITY
Surveys
NEWS
Current
Press
Archive
FEATURES
Editorial
Dr. Mac
Reviews
Reader Reports
RESOURCES
FAQ
Documentation
Learning Center
MAN pages
Glossary
Tutorials
Tips
Links

OUR PARTNERS


     dd [operands ...]


DESCRIPTION

     The dd utility copies the standard input to the standard output.  Input
     data is read and written in 512-byte blocks.  If input reads are short,
     input from multiple reads are aggregated to form the output block.  When
     finished, dd displays the number of complete and partial input and output
     blocks and truncated input records to the standard error output.

     The following operands are available:

     bs=n     Set both input and output block size, superseding the ibs and
              obs operands.  If no conversion values other than noerror,
              notrunc or sync are specified, then each input block is copied
              to the output as a single block without any aggregation of short
              blocks.

     cbs=n    Set the conversion record size to n bytes.  The conversion
              record size is required by the record oriented conversion val-
              ues.

     count=n  Copy only n input blocks.

     files=n  Copy n input files before terminating.  This operand is only ap-
              plicable when the input device is a tape.

     ibs=n    Set the input block size to n bytes instead of the default 512.

     if=file  Read input from file instead of the standard input.

     obs=n    Set the output block size to n bytes instead of the default 512.

     of=file  Write output to file instead of the standard output.  Any regu-
              lar output file is truncated unless the notrunc conversion value
              is specified.  If an initial portion of the output file is
              skipped (see the seek operand) the output file is truncated at
              that point.

     seek=n   Seek n blocks from the beginning of the output before copying.
              On non-tape devices, a lseek(2) operation is used.  Otherwise,
              existing blocks are read and the data discarded.  If the user
              does not have read permission for the tape, it is positioned us-
              ing the tape ioctl(2) function calls.  If the seek operation is
              past the end of file, space from the current end of file to the
              specified offset is filled with blocks of NUL bytes.

     skip=n   Skip n blocks from the beginning of the input before copying.
              On input which supports seeks, a lseek(2) operation is used.
              Otherwise, input data is read and discarded.  For pipes, the
              correct number of bytes is read.  For all other devices, the
              correct number of blocks is read without distinguishing between
              a partial or complete block being read.
              block    Treats the input as a sequence of newline or end-of-
                       file terminated variable length records independent of
                       input and output block boundaries.  Any trailing new-
                       line character is discarded.  Each input record is con-
                       verted to a fixed length output record where the length
                       is specified by the cbs operand.  Input records shorter
                       than the conversion record size are padded with spaces.
                       Input records longer than the conversion record size
                       are truncated.  The number of truncated input records,
                       if any, are reported to the standard error output at
                       the completion of the copy.

              ebcdic, ibm, oldebcdic, oldibm
                       The same as the block value except that characters are
                       translated from ASCII to EBCDIC after the records are
                       converted.  (These values imply block if the operand
                       cbs is also specified.)  There are four conversion maps
                       for EBCDIC. The value ebcdic specifies the recommended
                       one which is compatible with AT&T System V UNIX.  The
                       value ibm is a slightly different mapping, which is
                       compatible with the AT&T System V UNIX ibm value.  The
                       values oldebcdic and oldibm are maps used in historic
                       AT&T and pre 4.3BSD-Reno systems.

              lcase    Transform uppercase characters into lowercase charac-
                       ters.

              noerror  Do not stop processing on an input error.  When an in-
                       put error occurs, a diagnostic message followed by the
                       current input and output block counts will be written
                       to the standard error output in the same format as the
                       standard completion message.  If the sync conversion is
                       also specified, any missing input data will be replaced
                       with NUL bytes (or with spaces if a block oriented con-
                       version value was specified) and processed as a normal
                       input buffer.  If the sync conversion is not specified,
                       the input block is omitted from the output.  On input
                       files which are not tapes or pipes, the file offset
                       will be positioned past the block in which the error
                       occurred using lseek(2).

              notrunc  Do not truncate the output file.  This will preserve
                       any blocks in the output file not explicitly written by
                       . The notrunc value is not supported for tapes.

              osync    Pad the final output block to the full output block
                       size.  If the input file is not a multiple of the out-
                       put block size after conversion, this conversion forces
                       the final output block to be the same size as preceding
                       blocks for use on devices that require regularly sized
                       blocks to be written.  This option is incompatible with
                       use of the bs=n block size specification.
                       length of the input records is specified by the cbs
                       operand.  Any trailing space characters are discarded
                       and a newline character is appended.

     Where sizes are specified, a decimal number of bytes is expected.  If the
     number ends with a ``b'', ``k'', ``m'' or ``w'', the number is multiplied
     by 512, 1024 (1K), 1048576 (1M) or the number of bytes in an integer, re-
     spectively.  Two or more numbers may be separated by an ``x'' to indicate
     a product.

     When finished, dd displays the number of complete and partial input and
     output blocks, truncated input records and odd-length byte-swapping
     blocks to the standard error output.  A partial input block is one where
     less than the input block size was read.  A partial output block is one
     where less than the output block size was written.  Partial output blocks
     to tape devices are considered fatal errors.  Otherwise, the rest of the
     block will be written.  Partial output blocks to character devices will
     produce a warning message.  A truncated input block is one where a vari-
     able length record oriented conversion value was specified and the input
     line was too long to fit in the conversion record or was not newline ter-
     minated.

     Normally, data resulting from input or conversion or both are aggregated
     into output blocks of the specified size.  After the end of input is
     reached, any remaining output is written as a block.  This means that the
     final output block may be shorter than the output block size.

     If dd receives a SIGINFO (see the ``status'' argument for stty(1))  sig-
     nal, the current input and output block counts will be written to the
     standard error output in the same format as the standard completion mes-
     sage.  If dd receives a SIGINT signal, the current input and output block
     counts will be written to the standard error output in the same format as
     the standard completion message and dd will exit.

     The dd utility exits 0 on success and >0 if an error occurred.


SEE ALSO

     cp(1),  mt(1),  tr(1)


STANDARDS

     The dd utility is expected to be a superset of the IEEE Std1003.2
     (``POSIX'') standard.  The files operand and the ascii, ebcdic, ibm,
     oldascii, oldebcdic and oldibm values are extensions to the POSIX stan-
     dard.

BSD Experimental               January 13, 1994                              3

Copyright © 2000-2010 Inside Mac Media, Inc. All rights reserved.
Apple assumes no responsibility with regard to the selection, performance, or use of the products or services. All understandings, agreements, or warranties, if any, take place directly between the vendors and prospective users.
Apple, the Apple logo, Mac, PowerMac G4, PowerMac G5, Xserve, Xserve RAID, PowerBook, iBook, Airport, AirPort Extreme, iMac, eMac, iLife, iMovie, iCal, iPhoto, iTunes, QuickTime, FireWire, iPod, iSight, AppleWorks, Macintosh, Jaguar, Panther, Mac OS, Mac OS X and Mac OS X Server are trademarks of Apple Computer, Inc.